Product manual
SmartStor NS4300N Product Manual
92
Viewing UPS Status
If you have an APC Uninterruptable Power Supply (UPS) attached to the
SmartStor, you can check its status in PASM.
To view UPS status:
1. In the Tree, click on the + beside the Management icon.
2. Click on the APC UPS icon.
The Information tab displays the status of the UPS.
If there is no UPS connected or recognized, the Status field reports
“NO UPS.”
Setting up a UPS
To set up a UPS:
1. Attach the APC UPS to one of the SmartStor’s USB ports.
2. In the Tree, click on the + beside the Management icon.
3. Click on the APC UPS icon.
4. Click on the Setup tab.
The Setup tab enables you to tell the SmartStor how and when to shutdown
after a power failure.
Click the option button beside the shutdown option you want:
• Disable. The SmartStor will continue to run until the UPS battery is
depleted
• Shutdown when the UPS reaches a set percentage of reserve power
• Shutdown when the UPS reaches a set number of minutes of remaining
runtime
• Shutdown after running on the UPS batteries for a set number of
minutes
5. Optional. If you selected battery percentage, type a percentage amount in
the % field.
6. Optional. If you selected remaining runtime or running on batteries, type the
number of minutes into the Mins. field.
7. Click the OK button.