User guide

If you click the downward arrow at the right end of the tab, menu items used to change the tasks
priorities (Settings) and to start the tasks appear.
Settings menu
Rebuild Rate Sets the rebuild process priority. The default is Medium.
Logical Drive Initialization
Rate
Sets the logical drive initialization priority. The default is Medium.
Media Patrol Rate Sets the media patrol process priority. The default is Low.
Redundancy Check Rate Sets the redundancy check priority. The default is Medium.
Migration Rate Sets the expansion priority. The default is Low.
PDM Rate Sets the PDM priority. The default is Medium.
Transition Rate Sets the transition priority. The default is Medium.
Reassigned Block
Threshold
Sets the reassigned block threshold. The default is 32.
Error Block Threshold Sets the error block threshold. The default is 32.
Enable Media Patrol Enables or disables the media patrol process. The default is [Enable].
Enable Auto Rebuild Enables or disables whether the auto rebuild. The default is [Enable].
To return to the original values after changing some settings, click [Reset].
To change some settings and enable the new values, click [Submit].
To return to the recommended default values, click [Default] and afterwards click [Submit].
IMPORTANT: The information is set to proper values by
default. As a rule, do not change the settings.
- 30 -