User Manual
rebuilding A disk ArrAy
When you rebuild a disk array, you are actually rebuilding the data on one of its physical drives.
Ifthereisnosparedriveofadequatecapacity,youmustreplacethefaileddrivewithanuncongured
physical drive, then perform a Manual Rebuild.
On the carrier with the failed drive, the Drive Power / Status LED is red and the Drive Activity LED is
dark.
Drive carrier LEDs for a dead or failed drive
That is the physical drive you must replace.
PerforMing A MAnuAl reBuilD
To perform a manual rebuild:
1. Click on the Background Activities icon.
2. Mouse-over Rebuild and click the Start button.
3. From the Source Physical Drive dropdown menu, choose a Source disk array and physical
drive.
Arrays have an ID No. Physical drives have a Seq. No.(sequence number)
4. From the Target Physical Drive dropdown menu, choose a Target physical drive.
5. IntheConrmationbox,typetheword“conrm”intheeldprovidedandclicktheConrm
button.
When the disk array is rebuilding:
• The disk array shows a green check icon and Rebuilding status.
• Logical drives under the disk array continue to show a yellow ! icon and Critical,
Rebuilding status.
• Ifthebuzzerisenabled,thePegasusunitemitstwoquickbeepseveryveseconds.When
the beeps stop, the rebuild is done.
Red LED
Dark LED
68
Pegasus2 R4/R6/R8 Product Manual