User's Manual
VTrak J610s, J310s Product Manual
40
0488 500000E01122C0F3 0x10 CN1 ---- 0
0519 500000E01122C493 0x10 CN1 ---- 0
0731 500000E01122C5B3 0x10 CN1 ---- 0
0751 500000E01122C5C3 0x10 CN1 ---- 0
0851 500000E01122C583 0x10 CN1 ---- 0
0864 5000155D21AB433E 0x10 CN1 ---- 0
0945 500000E0112313C3 0x10 CN1 ---- 0
The route command displays SAS addresses that are attached to one of the
external ports on the J610s or J310s unit. Six items are reported:
• Entry Number – Arbitrary numbers, listed in sequence
• SAS Address – Of the disk drive or other component
• Port ID – Phy numbers, shown in hexadecimal
• Connector ID – One of two external SAS ports on the J610s or J310s unit
• Next Entry – The next entry number for the same SAS address
• Next Valid – 1 means there is another one. 0 means this is the last one
This device is connected to the J610s or J310s unit through connector CN1. See
page 21 for a diagram of connectors on the I/O module.
If you type route at the cli> prompt and press Enter, then see the following
message:
No SAS Routing Entry Exists
...it indicates that no devices are found on the table-routed (CN2) connector.
Uptime Command
The uptime command informs you of the elapsed period of time since the J610s
or J310s unit was powered on.
To display uptime, at the cli> prompt, type uptime and press Enter.
cli>uptime
System has been running 1 hour 46 minutes 35 seconds