User's Manual

Chapter 3: Management
35
I/O Module ID: 1 Max Num Of I/O Modules: 2
FwVersion: 1.00.0000.00 I/O Module Role: Primary
MaxNumOfHDSlots: 12 MaxNumOfPSUs: 2
MaxNumOfFans: 4 MaxNumOfBlowers: 2
MaxNumOfTempSensors: 8 MaxNumOfVoltageSensors: 5
===========================================
PSU Status Fan1Speed Fan2Speed
===========================================
1 Operational 14735 rpm 15037 rpm
2 Operational 15340 rpm 14361 rpm
===========================================
Blower Status Speed
===========================================
1 Operational 4017 rpm
2 Operational 4066 rpm
===========================================
ID Location Temp Reading ID Location Temp Reading
===========================================
1. Backplane 32C/89F 2. Backplane 32C/89F
3. Backplane 31C/87F 4. Backplane 30C/86F
5. I/O Module1 40C/104F 6. I/O Module1 30C/86F
7. I/O Module2 36C/96F 8. I/O Module2 28C/82F
Thermal Management: Enabled
Allows to shut down the system when critical temperature is reached: Yes
Current minimum fan speed setting: medium low
Enclosure Temp Threshold: 61C/141F (critical) 51C/123F (warning)
Controller Temp Threshold: 71C/159F (critical) 61C/141F (warning)
===========================================
VoltageSensor Voltage
===========================================
13.3V
25.2V
35.2V
4 12.5V
51.2V
Expander SAS Address:
SAS Base Addr:50 00 15 5D 21 AB 02 00
SSP SAS Addr: 50 00 15 5D 21 AB 02 3E
SMP SAS Addr: 50 00 15 5D 21 AB 02 3F
Attached SAS Address: