User Manual
VTrak E-Class Product Manual
144
6. Mouse-over the physical drive with the matching ID number and click the
Locate button.
The drive carrier LED blinks for one minute.
Running Spare Check
Spare Check verifies the status of your spare drives.
To run spare check:
1. Click the Storage tab.
2. Click the Spare Drive icon.
The list of spare drives appears.
3. Mouse-over the spare drive you want and click the Spare Check button.
4. Click the Confirm button.
After the “Spare Check completed” message appears, click the View button
to see Spare Check Status.
Running a Transition on a Spare Drive
Transition is the process of replacing a revertible spare drive that is currently part
of a disk array with an unconfigured physical drive or a non-revertible spare. You
must specify an unconfigured physical drive of the same or larger capacity and
same media type as the revertible spare drive.
See “Transition” on page 98 and page 284.
Running a Transition
To run a transition on a revertible spare drive:
1. Click the AdminTool tab.
2. Click the Background Activities icon.
The list of background activities appears.
3. Mouse-over Transition and click the Start button.
4. From the Source Physical Drive dropdown menu, choose a Source disk
array and the revertible spare drive.
Arrays have an ID No. The revertible spare has a Seq. No. (sequence
number).
Green LEDs
flash