User`s manual

FastTrak100 TX/LPSeries User Manual
81
About RAID Levels
Striping (RAID 0)
Reads and writes sectors of data interleaved between multiple drives. When any disk
member fails, it affects the entire array. Performance is better than a single drive
since the workload is balanced between the array members. This array type is for
high performance systems. Identical drives are recommended for performance as
well as data storage efficiency. The disk array data capacity is equal to the number
of drive members times the smallest member capacity. For example, one 1GB and
three 1.2GB drives will form a 4GB (4 x 1GB) disk array.
Stripe Size - a value can be set from 1KB to 1024KB sector size. The size can
directly affect performance. In the FastBuild BIOS, the “Desktop” default is 8KB while
“Server” and “A/V Editing” is 64KB.