Mirroring (RAID 1)
Writes duplicate data on to a pair of drives while reads are performed in parallel. ATA RAID
1 is fault tolerant because each drive of a mirrored pair is installed on separate IDE channels.
If one of the mirrored drives suffers a mechanical failure (e.g. spindle failure) or does not
respond, the remaining drive will continue to function. This is called Fault Tolerance. If one
drive has a physical sector error, the mirrored drive will continue to function.
RAID 1 (Mirroring)
On the next reboot, the FastBuild
TM
utility will display an error in the array and recommend
replacement of the failed drive. You may choose to continue using your PC, however we
recommend replacing the failed drive as soon as possible.
Due to redundancy, the drive capacity of the array is half the total drive capacity. For
example, two 1GB drives that have a combined capacity of 2GB would have 1GB of usable
storage. With drives of different capacities, there may be unused capacity on the larger drive.