4. Rebuild Wizard Step 2 confirms the target or “Rebuild” disk by Array # and drive ID.
5. Click “Finish” to initiate physical Rebuild, “Back” to review Step 2, or “Cancel” to Stop. A
final confirmation window appears as below:
6. Click “Yes” to initiate Rebuild. To cancel this option, click “No”.
WARNING: Once initiated, Array Rebuild CANNOT be halted. This is to prevent
data errors.
NOTE: During Array Rebuild, users may continue to access the array and perform normal
PC operations, however the array will NOT provide data redundancy until Rebuild is
completed. If you choose to continue using the PC during rebuild, system performance will
be slightly degraded and the process will take longer.
6. Once Array Rebuild starts, you will return to the FastCheck Monitoring window. A
progress bar showing the rebuild progress in percentage will appear at the bottom of the
FastCheck Monitoring window.