User manual

Chapter 3: FastBuild Configuration Utility
37
.
Follow these steps to use the Rebuild Array feature:
1. Press Ctrl-F to enter FastBuild Main Menu.
2. Select Define Array (3).
3. Press the arrow keys to select the Critical logical disk then press Enter to
select it.
The View Array Definition Menu appears (below).
In the example above, there is a two-drive Mirrored (RAID 1) logical disk.
Under Drive Assignments, the drive in Channel 1 appears but no drive
appears in Channel 2. This means the disk drive connected to Channel 2 is
the failed drive.
4. Power down your system.
5. Replace the failed drive with an identical or larger disk drive.
6. Reboot the system and enter the FastBuild Main Menu.
7. Select the Rebuild Array (5) option.
8. Press the arrow keys to select the Critical logical disk then press Enter to
select it.
Important
Drives MUST be replaced if they contain any physical errors,
before rebuilding the logical disk.
FastBuild (tm) Utility 2.03 (c) 2002-2005 Promise Technology, Inc
.
[ View Array Definition Menu ]
Logical Disk No RAID Mode Total Drv Status
Logical Disk 1 Mirror 2 Critical
Stripe Block: Not Available Gigabyte Rounding: ON
[ Drive Assignments ]
Channel ID Drive Model Capacity (MB)
1:SATA ST380023AS 80630
?:? Failed or disconnected
Any Key to Continue.....