User manual

Fast Trak TX2200 / TX4200 User Manual
20
Rebuilding The process of reconstructing a logical disk in Critical mode by
placing redundant data on a replacement disk drive.
Critical – Degraded logical disk condition due to a failed or removed disk drive.
Applies to mirrored logical disks (RAID 1 and 10) only. Fault tolerance is lost but
the data is still accessible. Triggers automatic rebuilding.
Offline Striped logical disks (RAID 0): Degraded logical disk condition due to
one failed or removed disk drive. The data is not accessible.
Mirrored logical disks (RAID 1 and 10): Degraded logical disk condition due to
two failed or removed disk drives. Fault tolerance is lost. The data is not
accessible.
If your logical disk goes Offline, contact Promise Technical Support for
assistance. See Appendix B.
Navigate the FastBuild Setup Menu
When using the menus, these are some of the basic navigation tips: Arrow keys
highlights through choices; the Space bar allows to cycle through options; Enter
selects an option; Esc aborts or exits the current menu.
Using the Main Menu
This is the first option screen when entering the FastBuild Setup.
FastBuild (tm) Utility 2.03 (c) 2002-2005 Promise Technology, Inc
.
[ Main Menu ]
[ Keys Available ]
View Drive Assignments ............[ 1 ]
View/Define Array..................[ 2 ]
Delete Array.......................[ 3 ]
Controller Configuration...........[ 4 ]
Rebuild Array......................[ 5 ]
Press 1..5 to Select Option [ESC]..Exit