Redundancy Check is an automated process of checking data and parity but it
only reports and does not correct, any inconsistencies that it finds.
Synchronization and Redundancy Check apply to RAID 1, RAID 5 and RAID 10
logical drives. When an logical drive is first created and you select Full
Initialization, the same action as Synchronization takes place.
To schedule Synchronization for all logical drives:
1. Click on the Logical Drive View icon in Tree View.
2. Click on the Synchronization Schedule tab in Management View.
3. In the Policy dropdown menu, select Fix if you want Synchronization or
Redundancy Check if you do not want to correct inconsistencies.
4. Click on the Enable radio button.
5. Click on the by Day, by Week or by Month radio button.
6. From the dropdown menus, select a start time and a day of the Week or
Month, if applicable.
Start time is based on a 24-hour clock.
7. Click the Schedule button.
If you want to cancel the scheduled Synchronization, do the following:
1. Click on the Logical Drive View icon in Tree View.
2. Click on the Synchronization tab in Management View.
3. Click on the Disable radio button.