User manual

WebPAM User Manual
60
If any bad sectors are found, they are listed here. WebPAM informs you by popup
and email messages when a bad sector error is logged (see page 38).
After 10 bad sectors have been discovered on a physical drive, WebPAM issues
a warning to replace the drive.
After 20 bad sectors have been discovered:
On fault-tolerant (RAID 1, 5 or 10) logical drives, the FastTrak controller will
set down the physical drive (take it offline) and the logical drive will go
critical.
Replace the physical drive and rebuild your logical drive.
On non-fault-tolerant (RAID 0) logical drives, the physical drive remains
online.
Backup your data, replace the physical drive, create a new logical drive and
copy your data to it.
See “Logical Drive Rebuild” on page 73 and “Logical Drive Critical / Offline” on
page 79.
See the FastTrak User Manual and SuperSwap User Manual for more
information about replacing a physical drive.
Locate a Physical Drive
When it becomes necessary to access a physical drive installed in a SuperSwap
enclosure, this function will help you identify the physical drive you want. To
locate a physical drive:
1. Click on the Physical Drive View icon in Tree View.
2. Click on the Physical Drive icon.
3. Click on the Locate Drive tab in Management View.