FastTrak SX4100 User Manual
12
Offline The logical drive is no longer operational and the FastBuild utility
cannot rebuild it. You must identify and replace the failed drive(s). Then you
can create a new logical drive and copy your data to it from the last tape
backup or other device.
For RAID levels 1, 5 and 10, at least two or more disk drives in the logical
drive have failed.
For a RAID 0 or JBOD logical drive, at least one disk drive has failed.
Main Menu
When the FastTrak BIOS displays on your computer screen, press Ctrl-F to
launch the FastBuild utility and display the Main Menu.
The Main Menu (above) has five options:
Press 1 to view disk drive assignments
Press 2 to create a logical drive or view information about an existing logical
drive.
Press 3 to delete a logical drive.
Press 4 to view and change controller configuration.
Press Esc (Escape) to exit the menu.