Chapter 3: FastBuild™ Utility
27
Setting a Disk Array as Bootable
You may select which defined array will be used as the bootable array from the
Define Array Menu (press 2 in the Main Menu). Press the up and down arrow
keys to highlight the desired array and press the Spacebar. The system will now
recognize this as the first array and an asterisk (*) will appear next to the array
number indicating it as bootable (see below).
FastBuild Array Utility 2.xx (c) 2002-2005 Promise Technology, Inc.
[ Define Array Menu ]
[ Keys Available ]
Array No RAID Level Total Drv Capacity (MB) Status
Array 1 RAID5 3 161260 Functional
Array 2 ----- ----- ----- -----
Array 3 ----- ----- ----- -----
Array 4 ----- ---- ----- -----
Note: * --Bootable Array
[ ] Up [ ] Down [ESC] Exit [Enter] Select [Space] Change Boot Drive
*
Figure 10. Assigning a Bootable Array.
Important
You must reconfigure your PC’s or server’s BIOS in order use
FastTrak card as the bootable controller. The system will then
use the bootable array as the (fixed) boot C: drive.