User manual

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual
10
FastBuild Array Utility 2.xx (c) 2002-2005 Promise Technology, Inc.
[ Define Array Menu ]
[ Keys Available ]
Array No RAID Level Total Drv Capacity (MB) Status
Array 1 ----- ----- ----- -----
Array 2 ----- ----- ----- -----
Array 3 ----- ----- ----- -----
Array 4 ----- ---- ----- -----
Note: * --Bootable Array
[ ] Up [ ] Down [ESC] Exit [Enter] Select [Space] Change Boot Drive
4. Press the arrow keys to highlight an array number you wish to define and
press Enter to select it. The Define Array Definition Menu will next appear
(below).
FastBuild Array Utility 2.xx (c) 2002-2005 Promise Technology, Inc.
[ Define Array Definition Menu ]
Array No RAID Level Total Drv Status
Array 1 RAID 5 3 Functional
Stripe Block: 64 KB Initialize Array: ON Gigabyte Boundary: ON
[ Drive Assignments ]
Channel ID Drive Model Capacity (MB) Assignment
1: SEAGATEST380023AS 80630 Array 1
2: SEAGATEST380023AS 80630 Array 1
3: SEAGATEST380023AS 80630 Array 1
4: SEAGATEST380023AS 80630 Free
[ Keys Available ]
[ ] Up [ ] Down [Space] Change Option [ESC] Exit [Ctrl-Y] Save
5. Choose the RAID Level you want. In the Define Array Definition Menu
section, press the Spacebar to cycle through array types:
RAID 0 (Striping)
RAID 1 (Mirroring)
RAID 0+1 (Striping / Mirroring)
RAID 5 (Data / Parity Striping)
JBOD (Single Drive)