Datasheet

VessJBOD 1740, 1840 Product Manual
32
0468 500000E01205B472 CN#2
0542 500000E01122C5B2 CN#2
0624 500000E0114E4A32 CN#2
0639 500000E0114D8E32 CN#2
0700 500000E0120B2A62 CN#2
0721 500000E0114DE7A2 CN#2
0751 500000E0114E5EA2 CN#2
0764 500000E0120B28F2 CN2
0765 500000E0114C2342 CN#2
0977 500000E0120A2472 CN#2
1023 5000155FFFC02408 CN#2
--------------------------------------------------------------------
The route command displays SAS addresses that are attached to the SAS ports
of the VessJBOD unit. Three items are reported:
Entry# – Arbitrary numbers, listed in sequence
SAS Address – Of the disk drive or other component
CnID – External SAS port connector
CN#1 is the SAS IN port, circle icon. CN#2 is the SAS OUT port, diamond
icon. See page 21, Figure 3.
Route Troubleshooting
If your system returns:
No SAS Routing Entry Exists
...it indicates that no downstream devices are found.
Uptime Command
The uptime command informs you of the elapsed period of time since the
VessJBOD unit was powered on.
To display uptime:
The I/O module supports cables from 1 to 8 meters in length.The system
returns:
System has been running 1 day 9 hours 46 minutes 36 seconds