Datasheet
VessJBOD 1740, 1840 Product Manual
28
8 DSK09 SAS 3.0G OK End ---- Rdy
9 DSK10 SAS 3.0G OK End ---- Rdy
10 DSK11 SAS 3.0G OK End ---- Rdy
11 DSK12 SAS 3.0G OK End ---- Rdy
12 DSK13 SAS 3.0G OK End ---- Rdy
13 DSK14 SAS 3.0G OK End ---- Rdy
14 DSK15 SAS 3.0G OK End ---- Rdy
15 DSK16 SAS 3.0G OK End ---- Rdy
16 CN#1 ---- ---- ---- ---- ---- ----
17 CN#1 ---- ---- ---- ---- ---- ----
18 CN#1 ---- ---- ---- ---- ---- ----
19 CN#1 ---- ---- ---- ---- ---- ----
20 CN#2 SAS 3.0G OK End ---- Rdy
21 CN#2 SAS 3.0G OK End ---- Rdy
22 CN#2 SAS 3.0G OK End ---- Rdy
23 CN#2 SAS 3.0G OK End ---- Rdy
Phy : PHY ID Port: Port Id Type: SAS or SATA
Rate: Rate 3G/6G Init: Init Passed Dev : Device Type
Link: Link Connected PRdy: Phy Ready
----------------------------------------------------------------------
The following items are reported in the table above:
• Phy – Each link is a PHY, numbered 0 through 23
• Port – DSK01 through DSK16 represent drive slots. Each slot has one PHY.
See “Drive Slot Numbering” on page 9.
CN#1 is the SAS IN port, circle icon. CN#2 is the SAS OUT port, diamond
icon. See page 21, Figure 3. Each port has four PHYs.
• Type – Physical drive type, SAS or SATA
• Rate – Physical drive data rate, 3.0 Gb/s
• Dev – Device type. End means an end device. Exp means an expansion
device
• Link – Normally, ---- is displayed. If there is a connection at the moment the
link command runs, it displays CONN
• PRdy – PHY Ready Status. If the port is ready, it displays Rdy
Viewing Link Statistics
To view link status:
1. At the cli> prompt, type link and press Enter.
2. Scroll down to Link Statistics.