Datasheet

Chapter 3: Management
25
Controller temperature threshold : 71C/159F (critical)
61C/141F (warning)
===============================================================
ID Location Voltage
===============================================================
1 I/O Module 4.825V
2 I/O Module 12.360V
---------------------------------------------------------------
Enclosure Settings List
The Enclosure command enables you to make settings for the enclosure.
Enclosure Warning Temperature – Measured at the backplane. Fan speed
increases until temperature falls below the threshold.
Enclosure Critical Temperature – Measured at the backplane.
Temperature value for automatic shutdown.
Controller Warning Temperature – Measured inside the I/O module. Fan
speed increases until temperature falls below the threshold.
Controller Critical Temperature – Measured inside the I/O module.
Temperature value for automatic shutdown.
Thermal Management Monitors enclosure temperature, adjusts fan
speeds, displays red LED on cooling unit when a fan fails
Automatic Shutdown – Shuts down the VessJBOD 30 seconds after the
enclosure or controller reaches critical temperature.
Minimum Fan Speed Specifies the minimum fan speed when the
VessJBOD reaches enclosure or controller warning temperature.
Making Enclosure Settings
To set the enclosure warning temperature to 51°C (141°F):
At the cli> prompt, type enclosure -a mod -s “enc_warning=51” and press
Enter.
Warning temperature range is 10° to 51°C (50° to 123°F)
To set the enclosure critical temperature to 61°C (141°F):
At the cli> prompt, type enclosure -a mod -s “enc_critical=61” and press
Enter.
Critical temperature range is 51° to 61°C (123° to 141°F)
To set the controller warning temperature to 51°C (141°F):
At the cli> prompt, type enclosure -a mod -s “ctrl_warning=75” and press
Enter.