24
When the cli> prompt reappears, the controller has rebooted.
Viewing Information
To view enclosure information:
At the cli> prompt, type enclosure and press Enter.
The system returns:
----------------------------------------------------------------
Time since system powerup: 1 day 9 hours 46 minutes 36 seconds
Enclosure : SAS JBOD 3U-16 Bay
Serial Number : Cx20j-12345
I/O Module ID : 1 Max I/O Module Cnt : 1
Firmware Version : 02.00.0000.xx I/O Module Role : Primary
Max HDD Slots : 16 Max Connectors : 2
Max PSU Cnt : 2 Max Fan Cnt : 2
Max Temp Sensor Cnt : 8 Max Voltage Sensor Cnt : 2
=================================================================
CU Status Fan1Speed Fan2Speed
=================================================================
1 Operational 4735 rpm 4037 rpm
===============================================================
ID Location Temp Reading
===============================================================
1 I/O Module 27C/80F
-----------------------------------------------------------------
Thermal Management : Enabled
Allows to shut down the system when
critical temperature is reached : Yes
Current minimum fan speed (1-4) : Level 1
Note
To reboot the VessJBOD enclosure:
1. Verify that no data I/O activity is in progress.
2. Turn the power supply switch (switches) OFF.
3. Wait 10 seconds. Turn the power supply switch
(switches) ON.