Datasheet
Chapter 3: Management
23
CN#1 is the SAS IN port, circle icon. CN#2 is the SAS OUT port, diamond icon.
See page 21, Figure 3.
To view the current settings:
At the cli> prompt, type cable and press Enter.
The system returns:
CN#1 Cable Length = 1 meter
CN#2 Cable Length = 1 meter
To set Expansion connector CN2 for a 3-meter cable:
At the cli> prompt, type cable -a mod -s “cn2=3” and press Enter.
The system returns:
Cable length of connector 2 is set to 3 meter
Enclosure Command
The Enclosure command:
• Enables you to reboot the VessJBOD enclosure (below)
• Displays information about the VessJBOD enclosure (page 24)
• Enables you to make enclosure settings (page 25)
Reboot the Controller
You can reboot just the controller (I/O module). This action might be needed to
help with setting changes on the VessJBOD.
To reboot the controller:
1. Verify that no data I/O activity is in progress.
2. At the cli> prompt, type enclosure -a mod -s “reboot=1” and press Enter.
Caution
A controller reboot does NOT meet the system restart
requirements for a firmware upgrade.