Chapter 3: Management
23
CN#1 is the SAS IN port, circle icon. CN#2 is the SAS OUT port, diamond icon.
See page 21, Figure 3.
To view the current settings:
At the cli> prompt, type cable and press Enter.
The system returns:
CN#1 Cable Length = 1 meter
CN#2 Cable Length = 1 meter
To set Expansion connector CN2 for a 3-meter cable:
At the cli> prompt, type cable -a mod -s “cn2=3” and press Enter.
The system returns:
Cable length of connector 2 is set to 3 meter
Enclosure Command
The Enclosure command:
Enables you to reboot the VessJBOD enclosure (below)
Displays information about the VessJBOD enclosure (page 24)
Enables you to make enclosure settings (page 25)
Reboot the Controller
You can reboot just the controller (I/O module). This action might be needed to
help with setting changes on the VessJBOD.
To reboot the controller:
1. Verify that no data I/O activity is in progress.
2. At the cli> prompt, type enclosure -a mod -s “reboot=1” and press Enter.
Caution
A controller reboot does NOT meet the system restart
requirements for a firmware upgrade.