Datasheet
VessJBOD 1740, 1840 Product Manual
22
CLI Command Set
The CLI uses the following set of commands:
cable – Specifies the length of cable for optimal signal quality. See page 22.
enclosure – Displays full information on the VessJBOD enclosure and its
components. See page 23.
factorydefault – Restores factory default settings. See page 26.
help – Use alone to see the list of commands. Use with a command to see a list
of options. Examples: enclosure -help or enclosure -h. See page 27.
link – Displays the current status of the PHYs (links), error counter, expander and
attached SAS addresses. See page 27.
route – Displays addresses of components through a downstream (expansion)
connection. See page 31.
uptime – Displays the number of days, hours, minutes and seconds since the
firmware was loaded (since the VessJBOD was started or restarted). See
page 32.
vpdr – Displays vital product data on field replaceable units. See page 33.
? – Use alone to see the list of commands. Use with a command to see a list of
options. Example: enclosure -? See page 33.
Cable Command
The Cable command displays the current cable length settings for the two SAS
ports. The I/O module supports cables from 1 to 8 meters in length.
LEDs
State
Dark Green Amber Red Blinking
Fan
Not
detected
OK
One fan
turning too
slowly
Multiple
fans turning
too slowly
—
I/O Module No power OK Error — —
SAS IN/
OUT Ports
No
connection
Port
connected
——
Green:
Activity
Note
Command options are NOT case-sensitive.