CA2000 AIR PURIFIER Please read in the User Manual carefully before using the product. Please keep the User Manual in good custody for reference.
Contents Foreword 2 Features 3 Safety Notices 4 Components 5 Control Switches 6 How to use 7 Maintenance 8 Technical Data 9 Circuit Diagram 10 Troubleshooting 11 Service 12 Warranty 12 Foreword Congratulations on the purchase of your Prolux CA2000 Air Purifier. Clean pure air is just a few steps away. Most people spend about 80% of their time indoors every day, so indoor air quality is very important to their health.
The CA2000 is equipped with a large surface sealed HEPA filter (for purifying large areas), carbon filter for odors and allergens, ionic cleaning for dust and dirt removal, automatic dirty air sensor, and multi-speed fan. We hope you and your family can enjoy cleaner healthier air through the use of Prolux’s latest Air Purifier. Welcome to the CA2000.
Safety Notices • • • • • • • • • • • • • • • • • Please do not disassemble, repair or modify the machine by yourself. Unauthorized servicing may cause fire or malfunction. Only use appliance on 120 volt-rated outlets. Do not use air purifier around water, pesticides, cleaning chemicals, grease, oil, water vapor, moisture or with wet hands as electric shock of fire may occur. Do not damage, change, or alter the air purifier in any way. If power line is damaged, fire and electric shock risk may result.
Air Purifier Components 1. 1. 2. 3. 4. 5. 6. 7. 8. 2. 3. 4. 5. Front Cover Pre-filter HEPA Filter Charcoal Filter Control Buttons Induction Cover (Sensor Inside) Air Flow Outlet Power Cord 5 6. 7. 8.
Function switch introduction 1. 1. 2. 3. 4. 5. 2. 3. 4. 5. Air Quality Sensor: Blue = Good, Red = Bad On/Off Switch Anion Switch Fan Speed Timer 1. Air quality- particulate sensor device is installed in the Air Purifier. During the first 3 minutes of starting up the unit, the air quality indicator light flashes red and blue alternately. After 3 minutes, if the air quality is good, air quality indicator light is blue.
3. Anion switch - Anion Air Purifier device is installed in the machine and it can release millions of anions to the air which helps clean the air and reduce allergens. Press ANION button and anion indicator light is on, displaying in blue. Anion function is in ON state at this time. Press ANION button again and anion indicator light is off, then anion function is in OFF state. 4.
1. Unplug the unit, then pull the front cover off and lift upwards so the front cover will come off. 2. Remove the pre-filter by pressing down on the two fasteners at the top of the filter. The filter is then removed. 3. Pull the HEPA filter towards you and remove it. 4. Pull the Carbon Odor Filter towards you and remove it. Assemble the Air Purifier For Installation of the Air Purifier filters, follow the previous steps in reverse.
decline. To clean it, blow out backwards lightly with compressed air OR rinse with warm water. Allow to properly dry before reuse. 3. HEPA Filter: When cleaning HEPA filter front side (back side will not need to be cleaned) you may knock or remove dirt (do not use water to clean) or lightly use compressed air. Please don’t press HEPA filter screen when cleaning. When filter screen replacement indicator lights up, contact your authorized dealer you bought the air purifier from to purchase additional filters.
Circuit Diagram 1. 2. 1. Air Quality Sensor 2. Motor 3. Anion Generator 10 3.
Troubleshooting Malfunction Unit unable to start Possible Reasons If the unit is not getting power from the cord. If the unit is not turned on. Solutions Check to make sure cord is firmly plugged into wall outlet. Check to make sure wall outlet is live and has electricity. Press the ON button to turn on unit. No air blown out Filter is clogged or dirty or filter is still in its plastic case. Remove the plastic packages around all filters and reinstall. Unit is turned to sleep mode (reduced power).
After-sale Service In case of any questions or warranty work, contact the authorized dealer where you purchased the unit. For fastest service when reporting a failure, please provide details such as your name, address, telephone number, product model and what the failure is. 3 Year Warranty Terms: 1. This Prolux CA2000 unit is covered by parts and labor for the length of 3 years from purchase date. 2. The warranty covers all parts of the unit except for filters. 3.