Setup guide

6201-WA-DFNT ProLinx Wireless Configure the ASCII Module
High Speed Wireless ASCII Generic Serial Gateway
Page 18 of 50 ProSoft Technology, Inc.
September 6, 2007
Producer Command Narrative for the First Command (line 1):
1 Send data using Unicast Mode
2 Send the data to IP Address 172.16.10.150.
3 Send 600 registers beginning at DB Register 0.
4 Do not set a Swap Code.
5 Send the data every 100 milliseconds.
6 Use an Exchange ID of 1000.
Producer Command Narrative for the Second Command (line 2):
1 Send data using Unicast Mode
2 Send the data to IP Address 172.16.10.150.
3 Send 600 registers beginning at DB Register 600.
4 Do not set a Swap Code.
5 Send the data every 100 milliseconds.
6 Use an Exchange ID of 1001.
Note: IP Address 172.16.10.150 is the 6201-WA-DFNT module.
The Consume commands perform the same function for data coming into the
module from the DFNT once configured.
1 3 4 5 2 6
Consumer Command Narrative for the First Command (line 3):
1 Consume data using Unicast Mode.
2 Consume this data only from IP Address 172.16.10.150.
3 Consume 600 words and store them beginning at DB register 1200.
4 Do not use a Swap Code.
5 Consume data within 400 milliseconds.
6 Only consume data with an Exchange ID of 1002.
Consumer Command Narrative for the Second Command (line 4):
1 Consume data using Unicast Mode.
2 Consume this data only from IP Address 172.16.10.150.
3 Consume 600 words and store them beginning at DB register 1800.
4 Do not use a Swap Code.
5 Consume data within 400 milliseconds.
6 Only consume data with an Exchange ID of 1003.
Note: The sample configuration file also shows an additional Produce and Consume
command. These commands are designed to pass a time value from the DFNT to the
ACSII module and then loop back from the ASCII to the DFNT. These commands are
included for testing and radio communication verification purposes only and are not
necessarily required for your application.