3. SPECIFICATIONS
Model PRO700
Capacity 650VA
Voltage Range 140 – 300VAC ± 5VAC Input
Frequency > 40 Hz
Phase Single + GND
Voltage Range 230VAC + 11% - 17% Output
Battery Mode 230VAC ± 10%
Frequency 50Hz ± 1Hz (Battery Mode)
Simulated Sine Wave (Battery Mode)
Waveform
Sine Wave (AC Mode)
Transfer Time 2ms typical
Type & Number 12V8.2AH – 1pc Battery
Backup Time 8 – 20 minutes depending on load
Recharge Time 90% Capacity after 8 hours
Short Circuit
Protection
Line mode – Fuse & software protection (CPU)
Battery mode – Software protection (CPU)
Protection/
Monitoring
Surge Protection Yes
Alarms Audible & Visual
Over Temperature
Protection
>75ºC Alarm will sound
>85ºC the system will shutdown
Line Mode: 100-120% 5 minutes change to fault mode
Overload
Protection
>120% change to fault mode immediately
Battery Mode: 100 – 120% 5 secs shut down;
>120% shut down immediately
Intelligent Battery
management
Prevent overcharging of battery.
Protect battery and prolong battery life.
Interface NA
9P D-Type
Connector
NA
Interface
Software (optional) NA
Noise <40dB General
Temperature 0ºC - 40ºC
Humidity 0% - 95% relative humidity
Power Factor Up to 0.7
Built-in AVR Full AVR (3 Steps)
*Specifications are subject to change without prior notice.