Connection to power supply
The socket should be connected in compliance with the relevant standard, to a dedicated
omnipolar circuit breaker. 30 A minimum supply.
Monophase 230V~ 1P+N
Put a bridge between terminal 1 and 2
Attach the green/yellow wire to the terminal Earth
The neutral N to the terminal 4
The phase L to one of the terminal 1 or 2
Biphase 400V~ 2P+N
Put a bridge between terminal 1 and 2
Attach the green/yellow wire to the terminal Earth
The neutral N to the terminal 4
The phase L1 to the terminal 1 and the phase L2 to the terminal 2
* calculated with the simultaneous factor following standard EN 60 335-2-6/1990
Caution! Ensure that you correctly attach the wires and the bridges and tighten the screws
properly.
We apologise for any inconvenience caused by minor inconsistencies in these instructions, which
may occur as a result of product improvement and development.
Kesa Electricals © UK: EC1N 6TE 20-07-2012
Mains Connection Cable diameter Cable Protection calibre
220-240V~ 50/60Hz
1 Phase + N 3 x 2,5 mm
2
H 05 VV - F
H 05 RR - F
25 A *
400V~ 50/60Hz 2 Phase + N 4 x 1,5 mm
2
H 05 VV - F
H 05 RR - F
16 A *
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
equipped with a faulty earth connection.