SS-969 SMD Rework Station 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 User’s Manual 1st Edition, 2011 ©2011 Copy Right by Prokit’s Industries Co., Ltd. Visit us at www.TestEquipmentDepot.
SAFETY INSTRUCTIONS WARNING Warnings and cautions are placed at critical points in this manual to direct the operator’s attention to significant items. They are defined as follows: WARNING: Failure to comply with a WARNING may result in serious injury or death. CAUTION: Failure to comply with a CAUTION may result in injury to the operator, or damage to the items involved. Two examples are given below. NOTE: A NOTE indicates a procedure or point that is important to the process being described.
** Do not strike the handpiece against hard surfaces or otherwise subject it to physical shock. ** Be sure the unit is grounded. Always connect power to a grounded receptacle. ** Do not disassemble the machine. ** Do not modify the unit. ** Use Pro’sKit provides replacement parts. ** Do not wet the unit or use the unit with wet hands. ** Remove power cord by holding the plug – not the wires. ** Make sure the work area is well ventilated.
Features: 1. Microprocessor-controlled, closed circuit sensor design, high power and quick warm-up times 2. Adjustable air flow, air volume and temperature, suitable for a variety of applications. 3. Handle with sensor design switching work & sleep mode for real-time operation convenience. 4. Auto Cool-Off Process to prolong the life of heating element 5. Plastic shell, compact body, beautiful, small footprint. 6. Comes with brushless motor provides long service life, quiet in operation 7.
Optional replacement Replacement Nozzle IC Package Model No. ID (mm) 9SS-969-A1 Ø4.5 9SS-969-A2 Ø7.5 9SS-969-A3 Ø11.2 Replacement Heat Gun Model No. Description Dimensions 5SS-969E-HG Heat Gun for 225x60x40mm SS-969E (110V) (wire length Heat Gun for 115cm) 5SS-969B-HG SS-969B/H (220V) 5SS-969E7-HG Heat Gun for SS-969E7 (127V) Application 1. Suitable for desoldering multiple components. Such as: SOIC, CHIP, QFP, PLCC and BGA etc. (especially for flat cables and cable connectors). 2.
5.Press “▲”or “▼”button as to set up the temperature. 6.Adjust the airflow knob to set up the required air volume. 7.Hold the handle, the equipment begins to heat. Adjust the knob of airflow in order to set proper air volume, operate normally when temperature is stable. 8.Put the handle back on the holder after work, the SMD station switched from heating mode to cooling - off mode automatically. When the temperature is lower than 100℃, the station switching to standby mode. 9.
Note: Explanation of Symbols A. “- - -“represents the temperature is lower than 100℃ in standby mode, and the handle put on the holder. B. “S-E” represents the switch turned on but the connector of heat gun did not connect to the station properly or the sensor of heat gun damaged, please replace a new heat gun. Terms of use 1. The air outlet and its surrounding area may be very hot. Be cautious of scald. 2. The heating handle shall not be put on the working table or other place except its holder. 3.
Basic troubleshooting guide WARNING To avoid personal injury or equipment damage, disconnect power cord before making any servicing to the equipment. Problem 1: The unit has no power / display does not light up. 1. Check if the unit is switched ON. 2. Check the fuse, replace with the same type of fuse if blown. 3. Check the power cord and make sure there is no disconnection. 4. Verify that the unit is properly connected to the power source. 5. Check if local voltage matches the product requirement.