Owner's manual

DC CURRENT
Range Resolution Accuracy
200uA 0.1uA ±(1.0% of rdg + 5 digits)
2mA 1uA ±(1.0% of rdg + 5 digits)
20mA 10uA ±(1.0% of rdg + 5 digits)
200mA 100uA ±(1.0% of rdg + 5 digits)
10A 10mA ±(2.5% of rdg + 5 digits)
Overload Protection: 0.2A/250V restorable fuse.
10A/250V fuse
AC VOLTAGE
Range Resolution Accuracy
200V 100mV ±(1.2% of rdg+10digits)
500V 1V ±(1.2% of rdg+10 digits)
Overload Protection: 500V DC or rms. AC for all ranges.
Frequency range: 40Hz to 400Hz. Response: Average
responding, calibrated in rms. of a sine wave.
DIODE & CONTINUITY
Range Description
If continuity exists (about less than 50Ω), built-in
buzzer will sound
Show the approx. forward voltage drop of the diode
Overload Protection: 250V DC or rms. AC.
5