Installation instructions
5
TENSIONED SCREEN INSTALLATION
UP
OFF
DOWN
THIS SWITCH CAN NOT
BE USED WITH LVC.
120V WIRING DIAGRAM WITH
OPTIONAL BUILT-IN VIDEO
PROJECTOR INTERFACE
120V WIRING DIAGRAM
FOR STANDARD
WALL SWITCH
240V WIRING DIAGRAM WITH
OPTIONAL BUILT-IN VIDEO
PROJECTOR INTERFACE
240V WIRING DIAGRAM
FOR STANDARD
WALL SWITCH
SPDT SWITCH WITH
CENTER OFF
AC (COMMON)
AC HOT 120VAC 60HZ 1 AMP
BLACK/YELLOW
BLACK
RED
WWHHIITTEE
BLACK (DOWN)
RED (UP)
JUNCTION BOX
LOCATED IN LEFT ENDCAP
WWHHII TT EE
BLACK
RED
GREEN
MOTOR
NOTE: A SINGLE SWITCH CANNOT BE USED TO OPERATE MORE THAN
ONE SCREEN. CONTACT THE FACTORY FOR FURTHER
INFORMATION.
WWHHIITTEE (COMMON)
BLACK
WWHHIITTEE (COMMON)
BLACK (DOWN)
RED (UP)
120VAC/60HZ
POWER SOURCE
UP
OFF
DOWN
THIS SWITCH CAN NOT
BE USED WITH LVC.
REAR OR DPDT SWITCH
WITH CENTER OFF
BROWN AND YELLOW AC HOT
220/240 VAC 50HZ 2 AMP.
BLUE AC COMMON
BROWN
BLUE JUMPER
WIRE
BLUE
BROWN (DOWN)
BLACK (UP)
JUNCTION BOX
LOCATED IN LEFT
ENDCAP
BLUE
BROWN
BLACK
GREEN
MOTOR
NOTE: A SINGLE SWITCH CANNOT BE USED TO OPERATE MORE THAN
ONE SCREEN. CONTACT THE FACTORY FOR FURTHER
INFORMATION.
BLACK
5/12 VOLT SCREEN TRIGGER ON PROJECTOR
GREEN (GROUND)
GROUND–MUST BE CONNECTED
TO BUILDING GROUND
GROUND TO CASE
GROUND TO CASE
GROUND–MUST BE CONNECTED
TO BUILDING GROUND
FIGURE 6 FIGURE 7
FIGURE 8
FIGURE 9
RED
BLACK (HOT)
GREEN (GROUND)
RED
BLACK
WWHHIITTEE
BLUE (COMMON)
BLACK
BLUE (COMMON)
BROWN (DOWN)
BLACK (UP)
240VAC/50HZ
POWER SOURCE
5/12 VOLT SCREEN TRIGGER ON PROJECTOR
GREEN/YELLOW (GROUND)
RED
BROWN (HOT)
GREEN/YELLOW (GROUND)
RED
BLACK
WWHHIITTEE
CAUTION: THE PROJECTOR MUST BE TURNED OFF BEFORE CONNECTING THE TRIGGER WIRES TO
THE PROJECTOR. FAILURE TO DO SO MAY DAMAGE THE CONTROLLER.
1. Use 2-conductor 20-24 gauge wire to extend the low voltage connection from the
projector’s 5 or 12-volt screen trigger output to the length required to reach the VPI.
When extending the low voltage connection from the projector’s screen trigger output,
be sure to maintain the proper polarity. The red wire from the VPI is the “signal” and
the black wire from the VPI is the “ground”.
2. Connect the wires from the VPI that are labeled “Low Voltage Connection” to the end
of the extended screen trigger wires above.
SEE NOTES
IN FIGURE 8.
FRONT OF
WALL SWITCH
BACK OF WALL
SWITCH
UP
STOP
DOWN
FRONT OF
WALL SWITCH
BACK OF WALL
SWITCH
UP
STOP
DOWN