SOLAR CONTROLLER SPECIFICATIONS
TYPE 3 Stage Automatic
INPUT 12V Solar Panels
MAXIMUM INPUT 25V
BATTERY 12V
ABSORPTION 14.4V
EQUALISATION 14.8V (When voltage drops below 11.1V)
FLOAT 13.7V
START 9V
APPROVALS EMC
BATTERY SIZES 250–1200CCA
300–1500MCA
40–200Ah
INSTALLATION & CONNECTION
STEP 1 Locate the panel in the best position
Locate the panel in a position where it is exposed to the sun for the majority of the day. For best
results use a northern orientation. The panel will function in the horizontal or hung position,
however for best performance tilt the panels so they directly face the sun.
STEP 2 Connect to the battery
Connect the 5 meter lead to the battery,
Red clamp to the positive (+) terminal and
Black clamp to the negative (-) terminal.
MAINTENANCE
Periodically inspect the electrical and mechanical connections. Make sure they are all tight and
free from corrosion. If necessary clean the surface of the solar panels with a soft damp cloth.
Mild detergent can also be used. Any dirt or residue on the glass may effect performance.