Manual
4
  LED OPERATION
Level 1
Level 2
Level 3*
Level 4
Green ON when solar is charging battery 
Green blink when the system is over voltage 
Green ON when battery level in the right range 
Green slowly flashing when battery level full 
Yellow ON when battery level low 
Red ON when loads cut off
Red slowly flashing when it is over load (the load amps is 1.25 times of rated   
current for 60 seconds, or the load amps is 1.5 times of rated current for 5 seconds) 
Red fast flashing when the load is short circuited 
Red ON when the switch is ON 
Red OFF when the switch is OFF 
  CHARGING STAGES
  Bulk Charge (Level 1) – Maximum current charging until batteries rise to Absorption level
  Absorption Charge (Level 2) – Constant voltage charging and battery is over 85%.
  Equalization Charge* (Level 3) – Only for WET battery or Calcium battery type, when the 
battery is deeply drained below 10V, it will automatically run this stage to bring the internal cells 
as an equal states and fully complement the loss of capacity.(Gel and AGM battery do not run 
Equalization charge)
  Float Charge (Level 4) – Battery is fully charged and maintained at a safe level. A fully 
charged battery has a voltage of more than 13.6 Volts.