  Battery Working Voltage Error
  If battery voltage does not match controller working voltage, controller will stop 
working. After correcting the voltage, the failure can be eliminated through pushing  
the load button.
  Damaged Temperature Sensor
  If the temperature sensor is short-circuited or damaged, the controller will be charging 
or discharging at the default temperature 25°C to prevent the battery damaged from 
overcharging or over discharge.
  Overheating Protection 
  If the temperature of the controller heat sink exceeds 85°C, the controller will 
automatically start the overheating protection and stop the charging and discharging. 
When the temperature is below 75°C, the controller will resume to work.
  High Voltage Transients
  Solar is protected against smaller high voltage surge. In lightning prone areas, 
additional external suppression is recommended.
  Note: The controller has daily automatic fault recovery function which will reduce  
the manual operation and can intelligently eliminate the fault caused by non-actual 
hardware failure.
  LOW VOLTAGE DISCONNECT (LVD)
  LVD will disconnect the DC load before the battery voltage falls too low, preventing 
damage due to over-discharge. Once the battery is recharged, the DC load will be 
automatically reconnected.
  LOAD CONTROL
  The SC320 & SC330 allow you to switch the DC load on/off from the controller without 
having to physically disconnect the load or appliance. When switched to ‘off’, the DC 
load is isolated from the battery ensuring maximum power conservation.
  ELECTRICAL PROTECTION
• Short circuit & over current protection
• Reverse polarity protection
• Conformal coated for protection against dust and moisture
  INSTALLATION
  General Installation Notes
•  Be very careful when working with batteries. Wear eye protection. Have fresh water 
available to wash and clean any contact with battery acid.
• Never short circuit the battery positive and negative terminals, and wires which may 
cause explosion or fire.
• Install external fuses/breakers as required.
• Disconnect the solar module and fuse/breakers near the battery before installing or 
adjusting the controller.