User Manual

9
  Control parameter
  Browse and modification operations are conducted over the control parameters  
of solar charge controller. See the scope of parameter modification in control 
parameters table, and the page of control parameters in the diagram below:
  Control parameters
 Parameters  Default  Range
  Battery type  Sealed  Sealed/Gel/Flooded/User
  Battery Ah  200Ah  1~9999Ah
  Temperature compensation 
coefficient 
-3mV/
o
C/2V -9–0mV/
o
C/2V 
  Rated voltage  Auto  Auto/12V/24V
  Charging SOC  100%  Fixed Value
  Discharging SOC  30%  10–80%
  Control parameters table
1.
Batt. type
Sealed
Batt.AH
xxxxAH
2.
Temp Comp.Coeff.
-M mv/
o
C/2V
Rated Voltage
Auto
3.
Over Volt. Disc.
xx.xV
Charge Limit
xx.xV
4.
Over Volt.Rec.
xx.xV
Equal. Charge
xx.xV
5.
Boost Charge
xx.xV
Float Charge
xx.xV
6.
Boost Rec.
xx.xV
Low Volt.Rec
xx.xV
7.
Under Volt.Rec.
xx.xV
Low Volt.Disc.
xx.xV
10.
Equalise Time
xxxMin
Boost Time
xxxMin
8.
Low Volt.Rec.
xx.xV
Discharge Limit
xx.xV
9.
Batt.Char. SOC
xxx%
Batt.DisCh. SOC
xxx%