User Manual

14
 Charging mode  Notes
  Vol.Compen.  Voltage compensation: Voltage control charging (default)
  SOC  By setting the charge and discharge SOC target values for battery charge 
  and discharge control
  Factory reset
  The default parameter values of solar charge controller could be restored via the Factory 
reset page, which means the “Control parameter”, “Load setting”, “Charge mode” and 
“Device password” of the devices could be restored to the factory defaults (the factory 
default password of the devices is “000000”).
  Failure information
  The current failure information of the solar charge controller could be checked via 
the Failure information page (a maximum of 15 failure messages could be displayed); 
when the failures of solar charge controller are eliminated, the corresponding failure 
information will also be automatically eliminated.
  Meter parameter
  The meter model, software and hardware version, and SN NO.could be checked via 
Meter parameter page. And the three parameters (Switch pages, Backlight, Audible 
alarm) could be browsed and modified as well.
  Note: When the set up is accomplished, the auto switch page cannot become effective 
until ten minutes later.
Factory Reset
Yes No
1. Over voltage
2. Over load
3. Short circuit
Failure Info.
2. 
Type: MT50
Ver: Hardware + Software
SN: XXXXXXXXXX
1.
Meter Para.
Sw-Pages: XXS
BKLight: XXS
AudiAlarm: on/off
Meter Para.