User Manual

7
LOAD MODE SETTING
Operating Steps
Under load mode setting interface, press SET button and hold on for 5 seconds until the
number begins flashing, then press MENU button to set the parameter, press SET button
to confirm.
1** Timer 1 2** Timer 2
100 Light ON/OFF 2 n Diabled
101 Load will be on for 1 hour 201 Load will be on for 1 hour
since sunset before sunrise
102 Load will be on for 2 hours 202 Load will be on for 2 hours
since sunset before sunrise
103–113 Load will be on for 3–13 hours 202–213 Load will be on for 3–13 hours
since sunset before sunrise
114 Load will be on for 14 hours 214 Load will be on for 14 hours
since sunset before sunrise
115 Load will be on for 15 hours 215 Load will be on for 15 hours
since sunset before sunrise
116 Test mode 2 n Disabled
117 Manual mode (Default load ON) 2 n Disabled
NOTE: Please set Light ON/OFF, Test mode and Manual mode via Timer 1.
Timer 2 will be disabled and display “2 n”.
BATTERY TYPE
Operating Steps
Under Battery Voltage interface, press SET button and hold on 5s then enter into the
interface of Battery type setting. After choosing the battery type by pressing MENU button,
waiting for 5s or pressing SET button again to modify successfully.
Battery Type
1. Sealed (AGM) 2. GEL 3. FLOODED
(default)
NOTE: Please refer to the battery voltage parameters table for the different battery type.