No. LED COLOUR STATUS DESCRIPTION
1 Mains GREEN ON AC input OK
OFF AC disconnected
4XLFNöDVKLQJöDVKWZLFHHYHU\VHFRQG AC input abnormal
2 Str Bat GREEN ON Alternator charging the SERVICE battery
6ORZöDVKLQJöDVKRQFHHYHU\VHFRQG Starter battery is >13.4V and is being charged by
the PM335
4XLFNöDVKLQJöDVKWZLFHHYHU\VHFRQG The Starter Battery is 2~13.4V or >16.0V, while
AC power is connected.
OFF Starter battery is disconnected.
3 PV
6RODU
GREEN ON Solar charging the battery
6ORZöDVKLQJöDVKRQFHHYHU\VHFRQG The input voltage of the Solar is normal but it is
charged by the AC or Starter battery
4XLFNöDVKLQJöDVKWZLFHHYHU\VHFRQG Solar input voltage error – Solar voltage >50Vdc
OFF Solar disconnected
4 CHG GREEN ON Battery charged
6ORZöDVKLQJöDVKRQFHHYHU\VHFRQG Battery charging
4XLFNöDVKLQJöDVKWZLFHHYHU\VHFRQG Battery discharge
OFF Battery disconnected
5 FAULT RED ON Short circuit
Flash once per cycle Service battery voltage low
Flash twice per cycle Service battery voltage high
Flash 3 times per cycle PM335 unit Over Temperature
Flash 4 times per cycle %XONFKDUJHWLPHRXW
Flash 5 times per cycle VCR anomaly
Flash 6 times per cycle Environment Over Temperature
Table 7 LED indicator description of PM335
Figure 21 An overview of PM335
5. DISPLAY
5.1 PM300 Power Management System
P/No. PM335