Manual

9
STEP 2C – PERMANENT HARD WIRING
It is possible to hard wire the DC charging leads to the battery for permanent
installations.
You will need 2 x ring terminals, an inline fuse holder and a fuse with the following
ratings. (See below)
PC400 = 7.5 Amp fuse
PC800 = 10 Amp fuse
PC1600 = 30 Amp fuse
PC2100 = 30 Amp fuse
Connection:
1. Cut off the supplied battery clips; ensure you leave sufficient cable to reach the
battery terminals. (DO NOT extend the battery charger DC leads, as the added
voltage drop will cause incorrect charging).
2. Fit a ring terminal to the BLACK Negative (-) wire.
3. Connect an inline fuse to the RED Positive (+) wire.
4. Connect a ring terminal to the other end of the inline fuse.
5. Connect the RED lead (with inline fuse and ring terminal) to the Positive (+)
battery post.
6. Connect the BLACK lead (with ring terminal) to the Negative (-) battery post.
7. Fit the correctly rated fuse.
If the charger is used in a Permanent/Hard Wired application and the vehicle will not
be used for some time, it is best to leave the charger connected to mains power (turned
β€˜On’) so that it can maintain the battery fully charged.
Ensure any modification to the 240V mains lead is carried out by a qualified person and
that connection to supply mains is in accordance with National wiring rules.
Inline fuse Ring terminal