Manual

12
FAULTS & ERRORS
There are 6 possible error signals that may be displayed. These are explained in the 
following table:
Fault  Bulk  Full  Rejuv
(Red LCD)  (Blue LED)  (Green LED)  (Amber LED)  Fault  Remedy
Solid On    Flashing 
–––––    – – – 
Flashing 
– – – 
Solid On      Flashing 
–––––    – – – 
Solid On  Solid On 
––––– –––––– 
Solid On 
––––– 
Solid On  Flashing 
–––––  – – –
Battery  
problem has 
been detected
Battery may  
be faulty and may 
need to be replaced
Bulk charging 
has timed out 
and stopped 
after 24 hours
Battery may  
be faulty
Move charger to  
a cooler location
OR
Check fan is  
working properly
Over 
temperature
Check battery or 
remove any load  
on the battery
Soft Start has 
timed out
Battery  
problem has 
been detected
Initiate Rejuvenation 
mode. If it fails again 
the battery may be 
faulty
Check the clips are not
touching each other
OR
Check the clips are
correctly connected  
to the battery
Short circuit  
or reverse 
connection  
of the clips