Manual
4
SPECIFICATIONS
P/No. IP150 IP300 IP600 IP1000
Input 12VDC Battery/Vehicle (9.75–15.5VDC)
Input Current (Max DC Amps) 15A 30A 60A 100A
No Load Current Draw 500mA 500mA 650mA 1200mA
Remote Standby Current Draw ––2mA 2mA
Output 240VAC 50Hz
Continuous Power (Watts) 150W 300W 600W 1000W
Peak Power (Watts) 300W 600W 1200W 2000W
Inverter Classification Equipotentially Bonded Inverter (EPB)
Output Waveform Pure Sine Wave
Efficiency 85–90%
Low Battery Alarm/Shutdown Alarm 10.25V, Shutdown 9.75V (±0.2V)
Cooling Fan Automatic Temperature Controlled
Thermal Shutdown 65ºC (±5ºC)
Replacement Fuse Standard Auto Blade
Fuse Quantity & Size 30A 60A 110A 220A
(1 x 30A) (2 x 30A) (2 x 40A & 1 x 30A) (4 x 40A & 2 x 30A)
Fuse Location Internal
Size (mm) 232 x 108 x 63 252 x 108 x 63 250 x 168 x 81 360 x 168 x 81
Weight 1.1kg 1.25kg 2.2kg 3.2kg
IP150-1000 Instruction Manual_1 3/02/12 11:01 AM Page 4