CALCIUM (BULK AND ABSORPTION 14.7 VOLTS, EQUALISATION AND 
RECONDITION UP TO 16 VOLTS)
This charge mode is best suited for Calcium batteries that have been deeply discharged 
and require an equalization charge to restore a full electrolyte reading. If the battery 
requires a simple ‘top-up’, the WET charge mode can be used.
LOCKING THE BATTERY CHARGER SETTINGS
Locking the battery charger settings will disable the CHARGE RATE & MODE keys from 
use. This function is ideal for hire vehicles etc as it prevents the chargers settings from 
being altered if the keys are touched.
To lock; press and hold the ‘CHARGE RATE’ and ‘MODE’ keys for 3 seconds until all the 
LEDs illuminate. This indicates the keys are now locked.
To unlock; press and hold and ‘CHARGE RATE’ and ‘MODE’ keys for 3 seconds until all 
the LEDs illuminate. This indicates the keys are now unlocked.
FAULT CODES
There are three error codes that may be displayed. These will be displayed in the 
following way:
 Power  Charging  Full  Fault  Remedy   
  (Red LED)  (Blue LED)  (Green LED)
 ___ ___ ___   
 (Slow Flash)  OFF  OFF   
 – – – – – – –     
 (Fast Flash)  OFF  OFF 
 ___ ___ ___     
 (Slow Flash)  OFF  ON 
Check clips are not 
touching each other 
OR 
Check the clips are 
correctly connected 
to the battery
Battery may  
be faulty
Battery may be 
faulty and may  
need replacing
OR
There is a load  
on the battery 
causing the battery 
to fail Analysis
The charger  
has entered 
recondition mode 
3 times and has 
timed out
Bulk charging 
has timed out 
and stopped 
after 22 hours
Short circuit  
or reverse 
connection  
of the clips