STEP 8 – CHECK THE ELECTROLYTE LEVEL (CALCIUM MODE ONLY)
Check the electrolyte level and top up if required.
MOUNTING INSTRUCTIONS
INTELLI-CHARGE Chargers are designed for indoor,  
out of weather use only. Ensure that both charger  
and battery are in a well-ventilated space during 
charging.
The battery charger end plates include a mounting 
flange for easy mounting. If permanently fixed the 
charger should be mounted to a suitable horizontal  
or vertical panel, with at least 10cm clearance from  
the end plates to provide adequate ventilation for  
the cooling fan.
PERMANENT WIRING TO BATTERY
It is possible to hard wire the DC charging leads to the battery for permanent 
installations. 
You will need 2 x ring terminals, an inline fuse holder and a fuse with a rating equal  
to or greater than twice the chargers output. (See below)
IC700 = use supplied wiring harness (15 Amp fuse) 
IC700W = 15 Amp fuse 
IC1000 = 20 Amp fuse 
IC1500 = 30 Amp fuse
Connection:
1.  Cut off the supplied battery clips; ensure you leave sufficient cable to reach the 
battery terminals. (DO NOT extend the battery charger DC cables, as the added 
voltage drop will cause incorrect charging).
2.  Fit a ring terminal to the BLACK Negative (-) wire.
3.  Connect the inline fuse to the RED Positive (+) wire.
4.  Connect a ring terminal to the other end of the inline fuse.
5.  Connect the RED lead (with inline fuse and ring terminal) to the Positive (+)  
battery post.
6.  Connect the BLACK lead (with ring terminal) to the Negative (-) battery post.
12V 7A 7-Stage
PWR SUPPLY
GEL
AGM
WET
CALCIUM
MODE
POWER ON
CHARGING
FULLY CHARGED
1A
2A
4A
7A
CHARGE
RATE
3.5mm 