Manual
10
ADJUSTABLE CHARGE RATES: 12 VOLT BATTERIES
STEP 5 – SET BATTERY CHEMISTRY TYPE
Battery Chemistry should be selected by the type of battery being charged (refer to  
the battery manufacturer’s specifications for battery type). Refer to page 12 for a 
detailed explanation.
For example if you are charging an AGM battery, then AGM mode will need to be 
selected. This can be done by the following procedure:
a.  Press the Mode or Charge Rate button.
b.  Press the Mode button repeatedly until the correct battery type is selected.
STEP 6 – CHARGING
During the charge process, the CHARGING and FULLY CHARGED LED will flash various 
patterns. This is normal and indicates the various charge stages. Refer to “How can I tell 
what stage the battery charger is in” in the FAQ section, page 14.
When the FULLY CHARGED LED remains on, this is known as the float stage and the 
charger can be left connected to the battery without over charging.
If the POWER LED is flashing, there is a fault; refer to “Fault Codes” explanation on  
page 13 of this manual.
STEP 7 – DISCONNECTION
Ensure the 240V mains switch is turned off and the charger is disconnected from the 
240V mains power.
Battery out of vehicle
Remove the BLACK lead (battery clip) from the battery. 
Remove the RED lead (battery clip) from battery.
Battery in vehicle
Remove the chassis connection. 
Remove the battery terminal connection.
Battery in vehicle using harness (IC700 only)
Unplug the harness from the charger’s output lead.
Current AH  CCA  MCA 
setting  C-7 C-20  C-7 C-20  C-7 C-20  Time
1A  7  20  40  120  55  170  7 – 24h
2A  14  40  80  240  110  330  7  –  24h
4A  30  80  180  480  250  650  7  –  24h
6A  40  120  240  720  330  1000  7  –  24h
7A  50  140  300  800  350  900  7  –  24h
8A  60  160  360  1000  500  1300  7  –  24h
10A  70  200  450  1000  500  1200  6  –  20h
15A  85  300  465  2000  600  2500  6  –  20h