Product Manual
WARNING
• PLEASE READ THESE INSTRUCTIONS COMPLETELY PRIOR TO INSTALLATION.
•  BATTERIES PRODUCE EXPLOSIVE GASES – Ensure no sparks or flames are present.
•  Wear eye protection.
•  Vehicles must be in “NEUTRAL ”or “PARK ”, park brakes “ON ”
•  Follow all vehicle manufacturer’s instructions.
•  Beware of moving parts.
•  Battery Isolators are designed for negative ground alternator systems with batteries 
of the same nominal voltage.
•  Batteries of differing voltages cannot be used.
FEATURES
• Easy to Install – The electronic isolator does not require any changes to the vehicle’s
existing wiring. It can be fitted to all 12V vehicle types.
•  Priority Charging for Starting Battery – Ensures that the starting battery is fully charged
before connecting the auxiliary battery in parallel.
•  Manual Override – If the starting battery is flattened and the auxiliary battery is charged, the
electronic isolator allows the batteries to be manually paralleled to jumpstart the vehicle.
•  Over-Current Protection – Protects the Isolator and charging system from over current
damage, which could occur due to a short circuit in the wiring.
•  Surge Protection – Provides surge protection for vehicles with electronic ignition/management
systems.
SPECIFICATIONS
PART NO.  DBC100  DBC150
VOLTAGE  12V  12V
CHARGING CURRENT  75A/100A peak  125A/150A peak
CHARGE TYPE  Parallel  Parallel
CONTROL  Electronic  Electronic
MOUNTING  Surface/firewall/battery side  Surface/firewall/battery side
CURRENT DRAW  Charging 500mA Charging 500mA
(Standby 30mA) (Standby 30mA)
VOLTAGE DROP  None  None
SURGE PROTECTION  Built in  Built in
2