Display and Status Indicators
The LCD display provides the operator with all sale information for the dispenser selected. It
also provides data such as time/date and shift totals reports when using the select functions.
Listed below in Table: Display Data are the various fields of data which may appear in the
display area, along with a brief description of each field.
Display Description
Pump #
Indicates the current/active dispenser #/fueling position.
Further key entry, such as authorization or payment will
apply to the current dispenser #.
Hose # Indicates the active hose at a fueling position.
Sale Type
Indicates the method of payment selected for a sale —
Cash (C) or Credit (R).
Sale #
Indicates which sale is selected — Current sale or previous
sale respectively (A or B respectively)
Product # Indicates the product type for the displayed sale.
Amount
Type
Indicates type of data being displayed in the amount field.
($) Sale amount, (V) Volume, (CG) Change amount, (LM)
Prepay Limit, (C) Cash, (R) Credit
Amount Indicates the value, dollar or volume of the active sale.
Entered
Value
Displays any data entered on the numeric keypad.
Table: Display Data