Do not replace the converter unless the following checks have been performed:
1. Loosen the screw on the positive terminal and disconnect the positive wire. Read the converter output voltage using a
DC voltmeter. The power converter is working properly if the voltage is above 13VDC (12V models), 26VDC (24V
models, 14.3VDC (12V 9100L models), and 28.4VDC (24V 9100-24L models).
2. If the converter output is zero volts, use an AC voltmeter to check for proper voltage at the 120VAC outlet that the
converter is plugged into. This voltage should be between 105 and 130 volts (206 and 265 volts for 230V models).
3. Check the fuses located at the front of the converter. These fuses will only blow if the battery or DC output leads
were connected in reverse, even for a moment. Replace the fuses and repeat step 1.
4. Disconnect optional Remote Pendant, TCMS Charge Wizard, or Remote Shutdown Module. Read the converter
output voltage using a DC voltmeter. The power converter is working properly if the voltage is above 13VDC (12V
models), 26VDC (24V models, 14.3VDC (12V 9100L models), and 28.4VDC (24V 9100-24L models).
NOTES:
When replacing fuse(s) it may be necessary to remove the TCMS plug or lithium shutdown module (if so equipped)
to provide clearance for fuse replacement.
Disconnect all power sources before replacing fuses.
TROUBLE SHOOTING GUIDE
PROBLEM POSSIBLE CAUSES ACTION
1. No Output
P
roper AC power not connecte
d
Connect power supply
Check AC distribution panel for proper operation
E
xternal Fuses Blown Check fo
reverse polarity
Replace fuses with same type and rating
Short Circuit Trace circuits fo
r
possible fault
U
nit has shutdown due to overheating Chec
k
ai
r
flow
Allow unit to cool
U
nit has shutdown due to over voltage
(Also see Item 4 below)
(No over voltage protection for 230V units)
Check input voltage
Converte
will shut down if the input voltage exceeds 132 Volts
Correct input voltage
Optional remote shutdown module is active.
(PD9100L only)
R
emove remote shutdown module.
2. External Fuses Blown
R
everse Battery Hook Up Correct hook up and replace fuses with same type and rating
3. Low Output Excessive load fo
r
converte
r
R
educe loa
d
requirements o
r
install large
r
converte
r
Input voltage not between 105-130 VAC
(205-265 VAC for 230V units)
Correct input supply voltage
Bad battery cell(s)
R
eplace battery
4. Intermittent or no Output on
Generator, works on Shore
Power
U
nit has shutdown due to over voltage.
A
dd anothe
r
load to the generator, this may reduce the “spikes” to
an acceptable level
Some generators exhibit excessive voltage
spikes on the AC power output, this may cause
the over voltage protection to shut the unit
down
Contact generator manufacturer for possible defect in the
generato
r
Remote Shutdown Module does not have
stable voltage.
Confirm Remote Shutdown Module voltage is between 5 and 30
V
DC