OPTIONAL REMOTE PENDANT
Your INTELI-POWER 9200 converter may have
been supplied with a Remote Pendant. The Remote
Pendant is optional on OEM but is included with all
retail models and plugs in to the accessory port of the
9200 series converter. While the built-in Charge
Wizard
automatically determines which operating
mode is best suited to recharge or maintain optimum
battery condition, the Remote Pendant allows for
manual override and has an indicator light to indicate
the mode of operation.
BOOST MODE - Indicated by green LED remaining
on.
NORMAL MODE - When the battery is between
50% and 90% charged, the green LED will flash once
per second. When the battery has reached 90% of
full charge the green LED will flash 2 - 3 times per
second.
STORAGE MODE - Indicated by green LED
flashing every 6 - 8 seconds.
MANUAL BUTTON - The manual button has been
provided to allow the operator to temporarily override
the converter (not recommended) or to verify the
converter is operating properly. For manual
operation, press and hold the button. The indicator
light will soon remain “ON” indicating Boost Mode.
Continue to hold the button and the light will blink
rapidly indicating the converter is in the Normal
Mode. Continue to hold the button until the light
blinks slowly indicating the converter is now in the
Storage Mode. After the manual button is released the
converter will stay in the selected mode. When the
battery charge status changes, the converter will
return to the automatic mode of operation to prevent
damage to the battery.
If a REMOTE PENDANT was not provided with
your INTELI-POWER 9200 Series converter, you
can purchase one from your local RV dealer or
online at www.progressivedyn.com
OPTIONAL TCMS CHARGE WIZARD
Your INTELI-POWER 9100 converter is equipped
with a TCMS interface. The TCMS Charge Wizard
pendant plugs into the TCMS interface to provide
computer control and monitoring of your batteries
charge state. The Charge Wizard
automatically
determines which operating mode is best suited to
recharge or maintain optimum battery condition. The
Charge Wizard
Pendant allows for manual override
and has an indicator light to indicate the mode of
operation.
BOOST MODE - Indicated by green LED remaining
on.
NORMAL MODE - When the battery is between
50% and 90% charged, the green LED will flash once
per second. When the battery has reached 90% of full
charge the green LED will flash 2 - 3 times per
second.
STORAGE MODE - Indicated by green LED
flashing every 6 - 8 seconds.
MANUAL BUTTON - The manual button has been
provided to allow the operator to temporarily override
the converter (not recommended) or to verify the
converter is operating properly. For manual
operation, press and hold the button. The indicator
light will soon remain “ON” indicating Boost Mode.
Continue to hold the button and the light will blink
rapidly indicating the converter is in the Normal
Mode. Continue to hold the button until the light
blinks slowly indicating the converter is now in the
Storage Mode. After the manual button is released the
converter will stay in the selected mode. When the
battery charge status changes, the converter will
return to the automatic mode of operation to prevent
damage to the battery.
The TCMS Charge Wizard Pendant can be
purchased from your local RV dealer or online at
www.progressivedyn.com
OPTIONAL REMOTE SHUTDOWN MODULE
Your INTELI-POWER 9100L converter is equipped
with a Remote Shutdown Module interface. The
converter can be shutdown using either a high or
low side control, or by connecting two wires by
means of a mechanical switch or relay contacts.
This allows the battery management system to
shutdown the converter after battery charging and
balancing are complete.