Problem Possible cause Solution
The room temperature is
too high.
Refer to climate class chart on
the rating plate.
Food products placed in
the appliance were too
warm.
Allow food products to cool to
room temperature before stor‐
ing.
The door is not closed cor‐
rectly.
Refer to "Closing the door".
The IntensiveCooling is
switched on.
Refer to "IntensiveCooling
function".
There is too much frost and
ice.
The door is not closed cor‐
rectly or the gasket is de‐
formed/dirty.
Refer to "Closing the door".
The water drainage plug is
not correctly positioned.
Position the water drainage
plug in the correct way.
Food products are not
wrapped properly.
Wrap the food products better.
Temperature is set incor‐
rectly.
Refer to "Operation" .
The compressor does not
start immediately after
pressing the IntensiveCool‐
ing, or after changing the
temperature.
This is normal, no error
has occurred.
The compressor starts after a
period of time.
Water flows on the rear
plate of the refrigerator.
During the automatic de‐
frosting process, frost
melts on the rear plate.
This is correct.
Water flows inside the refrig‐
erator.
The water outlet is clog‐
ged.
Clean the water outlet.
Food products prevent
that water flows into the
water collector.
Make sure that food products
do not touch the rear plate.
Water flows on the floor. The melting water outlet is
not connected to the evap‐
orative tray above the
compressor.
Attach the melting water outlet
to the evaporative tray.