56 progress
50°C (above room temperature) at any point
along its length.
After the connection has been carried
out, the heating elements must be tested by
being operated for about. 3 minutes.
Terminal block
The appliance is fitted with an easily-ac-
cessible 6-way terminal block, with its links
already set for operation on a 400V supply
with neutral (see illustration).
In the case of a different supply voltage,
the terminal block links must be turned in
line with the schemes shown in the
illustration. The protective conductor is
connected to the
terminal. After
connection, secure the cable to the terminal
block with strain relief.
Electrical connection to the hob
Attention - observe the installation
instructions for hob, built-in cooker
or control box!
This appliance can be connected to the
hob models specified in the «Technical data»
section. The socket for connecting the hob is
located on the cooker housing. The
connecting cables of the heating elements
and the protective conductor cable are
brought out from the built-in hob; these
cables are fitted with plug connections.
Insert the plugs and connecting cables in the
appropriate sockets. This prevents any
possible wrong connection.
The manufacturer accepts no
liability if the safety measures are not
observed.
230V 3~
1 2 3 4 5
L1 L2 L3 PE
230V 1~
1 2 3 4 5
L1 N PE
400V 2N~
1 2 3 4 5
L1 L2 N PE
400V 3N~
1 2 3 4 5
L1 L2 L3 N PE
Ø 4x2,5 mm²
Ø 3x4 mm²
Ø 4x2,5 mm²
Ø 5x1,5 mm²