User manual

ready set for operation on a 400V supply with
neutral (see illustration).
In the case of a different supply voltage, the
terminal block links must be turned in line
with the schemes shown in the illustration.
The protective conductor is connected to the
terminal.
After connection, secure the cable to the ter-
minal block with strain relief.
1 2
3
4
5
Electrical connection to the hob
Important! Observe the installation
instructions for hob, built-in cooker or
control box!
This appliance can be connected to the hob
models specified in the «Technical data» sec-
tion.
The socket for connecting the hob is located
on the cooker housing.
The connecting cables of the heating ele-
ments and the protective conductor cable
are brought out from the built-in hob; these
cables are fitted with plug connections.
Insert the plugs and connecting cables in the
appropriate sockets.
This prevents any possible wrong connec-
tion.
The manufacturer accepts no liability if
the safety measures are not observed.
Installation instructions
For ensuring a trouble free use of the installed
appliance, the unit or the column where the
appliance is to be installed should have ap-
propriate dimensions.
In accordance with the regulations in force,
all parts which ensure the shock protection
of live and insulated parts must be fastened
in such a way that they cannot be undone
without tools.
These also include the fixing of any end walls
at the beginning or end of a line of builtin
units.
The shock protection must in any case be
ensured by the building in of the appliance.
The appliance can be placed with its back or
a side wall against higher kitchen units, ap-
pliances or walls. However, only other appli-
ances or units of the same height as the ap-
pliance can be placed against the other side
wall.
Oven dimensions (see figure)
594
7
20
570
590
540
560
18 progress