Operation Manual
77 progress
Installation and connection must
be done in compliance with the
regulations in force. Any
interventions must be carried out
when the appliance is switched
off. Only qualified service
engineers may repair the
appliance
The manufacturing company
disclaims any liability if the safety
measures are not observed.
Connecting to the electrical supply
Before connecting to the electrical sup-
ply, please make sure:
- The fuse and the domestic electrical in-
stallation must be designed for the max.
load of the appliance (see rating plate).
- The domestic electrical installation must
be equipped with a proper earth con-
nection in accordance with the regula-
tions in force.
- The socket or the multi-pole off switch
must be easy to access after the appli-
ance has been installed.
This appliance is supplied with a con-
nection cable incorporating a standard plug,
suitable for the total electric load shown on
the rating plate. The plug is to be inserted
into a suitable wall socket.
The following types of mains cable are
suitable, taking the necessary rated cross
section into account:
H07RN-F, H05RN-F, H05RR-F, H05VV-
F, H05V2V2-F (T90), H05BB-F.
If the appliance is connected without a
plug, or if the plug is not accessible, a multi-
pole off switch (e.g. fuses, circuit breaker)
with a minimum gap of 3 mm between the
contacts must be installed between the ap-
pliance and mains cable. The switch must
not interrupt the earth wire at any point. The
yellow-green earth wire should be 2-3 cm
longer than all other cables.
The connection cable must always be
laid out so that at no point does it reach
50°C (over room temperature).
After the connection has been carried
out, the heating elements must be tested by
being operated for about 3 minutes.
Terminal block
The oven is fitted with an easily
accessible terminal block which is designed
to operate with a single-phase power supply
of 230 V.
Instructions for the Installer